Tag Archives: Simi Valley SB 326 deck inspectio

San Luis Obispo HOA Retains William Leys Waterproofing Consultants LLC For SB 326 Balcony Inspections

We are pleased to announce that we have been selected to perform the balcony inspections required under SB 326 by the Board of Directors of an HOA in San Luis Obispo.

Tumbling Waters HOA San Luis Obispo

The condominium association has 68 decks requiring Stage 1 inspections. Bill Leys, President of William Leys Waterproofing Consultants said he is extremely excited to see the number of Associations who are contracting with the firm for these important inspections. “We have a lot of deck inspections scheduled for most of the summer and are scheduling some jobs into October already, the demand is really ramping up.” said Leys.

Leys recommends that Associations start getting bids now and getting inspections scheduled ASAP. “There’s a point where we will reach full capacity and I anticipate we will be pretty booked for inspections through the end of the year and into 2024 within the next 4 months. There are not many inspectors and structural engineers who are doing balcony inspections and those that are, are telling me they’re booking up rapidly as well.”

Reach out to us today, drop us an email using the contact form on the left side of your screen, or call Bill Leys directly at 805-801-2380.

Pasadena HOA Selects William Leys Waterproofing Consultants LLC For Their Balcony Inspections

We are excited to announce that we have been selected to perform the balcony inspections for an HOA in Pasadena CA by the Board of Directors.

Cantilevered decks in Pasadena will be inspected by William Leys Waterproofing Consultants LLC

The Associations cantilevered decks are subject to SB 326 requirements and we brought a very competitive cost to perform Stage 1 inspections. We are pleased to be the firm selected from amongst very worthy peers who also bid this project.

When your Association is ready to get a proposal for balcony inspections we hope to reach out to us. We guarantee that we have no conflicts of interest, we guarantee that we only use a Structural Engineer who will inspect and then sign your report and we do our best to bring you the best price in the industry. Contact us today using the contact form on the left side of this web page or call Bill Leys directly at 805-801-2380.

Palm Springs HOA Selects William Leys Waterproofing Consultants LLC To Perform SB 326 Inspections on Their EEEs

We are pleased to announce that we have been selected to perform inspections under SB 326 for a property in Palm Springs CA. With over 70 EEEs to inspect, the association sought inspection quotes from some of the best inspection companies in California. We are honored to be thought of as highly as Sigler & Associates, A7 and Focused Inspection Group and asked to bid this job.

The Board of Directors interviewed each company after reviewing their proposals. I specifically told the Board during my interview that if our company lost the job, that I knew they had competent bidders that had no conflicts of interest and that I could sleep soundly knowing that they would be in good hands if they selected another company. I continually warn my managers that there are unsavory deck inspectors that are only seeking to take advantage of unsuspecting HOAs that are easy marks. We guarantee that we have no conflicts of interest. Some deck inspectors own waterproofing companies that want to do the repairs without you getting three competitive bids…

People say I’m crazy to talk up my competitors, but I don’t look at these companies as competitors, I look at them as peers worthy of respect and that they represent our industry well. I’m happy that we were awarded the job… And look forward to bringing your Association competitive bids against my worthy peers. May your association win the best inspection it deserves.

Your association deserves the best inspector who has zero conflicts of interest.

Call me, Bill Leys the Deck Inspector at 805-801-2380 for a fast free quote on your SB 326 inspection. We’ll be happy to bid against our peers and so will they.

Shoreline Condominiums Retains William Leys Waterproofing Consultants LLC For Their SB 326 Inspections

We are pleased to announce that Shoreline Condominiums in Santa Barbara has selected William Leys Waterproofing Consultants LLC to perform their SB 326 balcony inspections.

Shoreline Condominiums has over 60 decks, multiple walkways and bridges for pedestrians and numerous stairs supported by wood framing that requires inspection under the bill.

Clients understand how important choosing the right inspection company is to perform these vital inspections and appreciate that I guarantee in writing that I have no conflicts of interest. I don’t own a waterproofing company or have any interest in any company’s products that I might specify to repair your decks.

Call me today to schedule a free EEE evaluation of your property. 805-801-2380. Ask for Bill,bI answer the phone every time and you’ll be in good hands.

William Leys Waterproofing Consultants LLC Signs Two New SB 326 Inspection Contracts

We are proud to announce that we’ve recently signed agreements with Bella Villeta HOA in Santa Barbara and Hueneme Shores HOA in Port Hueneme for SB 326 balcony inspections.

Bella Villeta HOA is managed by The Management Trust Santa Barbara division and Hueneme Shores HOA is managed by Community Property Management of Camarillo.

Bill Leys, president and owner of William Leys Waterproofing Consultants LLC said ” Managers are reporting to us that our bids are very competitive, our proposals are detailed and very informative and that, along with our guarantee of no conflicts of interest, has led the way in Boards of Directors having an increased trust that they are hiring a reliable firm with years of experience in inspecting decks.”.

Leys has been advocating for deck inspections and inspecting decks since 2007… Long before Berkeley happened and has been a front runner in developing inspection standards, testifying at California State Senate hearings on the balcony bills in 2017.

HOAs and managers needing SB 326 inspections should contact us to get their free EEE evaluation and proposal for the required inspections.

The SB 326 Balcony Inspection Industry is Awash With Clowns

“Don’t you love farce?
My fault, I fear
I thought that you’d want what I want
Sorry, my dear!
But where are the clowns
Send in the clowns
Don’t bother, they’re here…” (lyrics by Stephen Sondheim)

I have noticed more and more deck waterproofing and general contracting companies that are suddenly becoming SB 326 balcony inspectors. They try to disguise themselves as balcony inspectors, but the giveaway as to what their true intentions are obvious when you start looking at their websites and offerings…

I see one company in Los Angeles that advertises 50% off balcony inspections; “savings” are applied to repairs…

I see a deck inspection company in Palm Springs that is owned by the same person who owns a waterproofing company out there…

I see a company in Los Angeles that is named after an African animal that looks like a horse saying that they will start demoing your decks and then have the structural engineer come inspect…

Watch out for clowns!

Currently the industry is under assault by less than ethical contractors who mislead their clients, use illegal contracts, have attorneys on their payroll that enforce illegal contracts and are just seeking to separate you from your reserve accounts.

They hide behind their reports which are written to suit their needs to try to force you to replace perfectly good balconies by saying that their useful life is a year or less. They use scare tactics, high pressure and lawyers that have the ethics of cockroaches.

When sorting the wheat from the chafe in finding a balcony inspector one must be diligent. Do background checks on the company You can use the secretary of state’s business portal to find who owns what, check Yelp and Google reviews, ask for references, check with other HOA managers about their experience. Insist that your balcony inspector sign a no conflict of interest statement. Insist that your balcony inspector has no ownership interest in any waterproofing or contracting company.

We here at William Leys Waterproofing Consultants LLC guarantee that we have no conflicts of interest in owning a waterproofing company, any material manufacturer or have any conflicts of interest that would interfere with putting the HOA’s best interest ahead of ours. Reach out today, we don’t have any clowns here.

Do My Decks, Stairs Walkways or Balcony’s Need To Be Inspected?

Lots of people are confused about the SB 326 balcony bill. Inspectors sometimes are too. We get lots of questions about whether an Association EEE’s must be inspected under the bills inspection requirements.

To make it a little easier we compiled this series of photographs showing what types of EEE’s must be inspected and which are exempt. We hope this helps a bit in understanding.

Do you need an SB 326 deck inspection? Call me, Bill Leys, The Deck Inspector today at 805-801-2380 to discuss and set up an appointment to personally evaluate your Associations EEE’s as to whether they must be inspected or if they are exempt.

Starting with decks ad balconies, here are some examples that need to be inspected….

This is a wood framed cantilevered balcony. It is eligible to be inspected under SB326.
This is a stucco covered cantilevered balcony. This is required to be inspected under SB 326.
This balcony, even though it only partially extends past the building, is required to be inspected under SB 326
These stacked balconies need to be inspected under the balcony bill
This balcony is extended out and supported by wood framing, it needs to be inspected under
SB-326.
This is a cantilevered wood framed balcony; it must be inspected under SB 326.
There’s actually 3 balconies here that must be inspected under SB 326.
This type pf balcony is eligible for inspection under SB 326. Only 3 walls support it, where 4 are required to exempt the balcony from inspection.

Next are examples of stairs and landings that need to be inspected, with one example of steel stairs that don’t need to be inspected (but the connection of them to the wood framing does need to be inspected).

So here we have concrete stairs attached to wood framing. The stairs need to be inspected under SB 326. Often times we will find dry-rot starting in the bottom where the wood contacts the concrete.
Here is a wood framed landing 6′ or more off the ground. This is eligible for inspection under SB 326. Note that the stairs are concrete with steel framing. These do not need to be inspected, but the connection too the wood framing does need to be inspected.
These stairs are required to be inspected under SB 326.

Walkways supported by wood framing need to be inspected, such as these examples.

Walkways like these need to be inspected under the SB 326 balcony bill
The walkways shown here are required to be inspected under SB 326.

So what type of deck/balcony/stair or walkway doesn’t need to be inspected? Anything that is less than 6′ high off the ground (don’t be surprised though is it’s 5′ off the ground and we want to inspect it), made of concrete or steel. And any deck supported by 4 walls like this one below. A solid wall (no columns) must support the deck all the way around for it to be exempt.

This balcony is supported by 4 walls and is therefore exempt from the bill. We still suggest that the railings be inspected.
This balcony on the other hand does need to be inspected despite it being recessed in and under a roof, as it is not supported by four walls like the balcony shown above. It is supported by framing across the lower opening (which is a patio on the first floor).

This pictorial is not meant to be exhaustive; if you aren’t sure after looking through our pictures, give a call or fill out our contact form. Sending us some pictures always helps too! We are here to help and guide you through the SB 326 process.